| Refrigeration |
Manufacturer |
Model |
Serial Number |
Notes |
|
Cryo-Quip Inc |
10,000 SCFH |
54407-1-23, 54407-1-6 |
Year 2006 |
|
Cryo-Quip Inc |
6000 SCFH |
53981-1-10 |
Year 2005 |
|
Vilter |
450XL - 16 Cylinder |
63744 |
300HP Motor, Size A11K4516XLD |
|
Vilter |
450XL - 6 Cylinder |
81964 |
125HP Motor, Size A12K456XLB |
|
Vilter |
450XL |
- |
|
|
Vilter |
444 |
- |
|
|
Vilter |
A12K448B |
31076 & 31072 |
8 Cylinder |
|
Vilter |
VSM361 VVR-A-H-NEC-WC |
K68955 |
Year 2006, 150HP, Vantage Microcontroller, Tube and Shell Heat Exchanger
|
|
Vilter |
VSM361 VVR-A-H-NEC-WC |
K15537 |
Year 2000, 150HP, Vantage Microcontroller, Tube and Shell Heat Exchanger
|
|
Vilter |
AH448 |
21393 |
96 Ton |
|
Vilter Manufacturing |
448 |
- |
Ammonia Compressor, 100 HP, 8 Cylinder, skid mounted |
|
Vilter Manufacturing |
AH14412RD |
15568AHRCD |
Skid Mounted Ammonia Compressor - 150 HP, 12-Cylinder |
|
Vilter Manufacturing |
AH14416RD |
13033AHRD |
Skid Mounted Ammonia Compressor - 200 HP, 16 - Cylinder |
| - |
- |
- |
- |
Top Of Page |

| Evaporative Condensers |
Manufacturer |
Model |
Serial Number |
Notes |
|
BAC |
C2663M |
92600021P |
436 Tons, 3rd18' x 10' x 12' |
|
Baltimore Aircoil |
VC2-491 & VXMC340 |
96100963 & 831440 |
Year 1996, 391 Tons & 266 Tons |
|
Evapco |
PMCB 690 |
MO35103 |
Still Installed - Removal in June 2008, 690 Tons, Includes all Pipes, Pumps, and Valves |
|
Evapco |
ATW-22A2 |
971183 |
56 GPM |
|
BAC |
CXV103 |
4052807101MAD |
103 Tons, Like New Condition, Includes Ammonia Reciever Tank |
|
Evapco |
ATC-191 5/2 |
974822M |
Year 1997, 700 Ton, Includes Ammonia Reciever |
|
Imeco |
AEC536 |
2102-1-RH
2102-1-LH |
Includes Ammonia Reciever, Overall Assembled Dimensions 21' x 17' x 10' |
| - |
- |
- |
- |
Top Of Page |

| Ammonia Receivers |
Manufacturer |
Model |
Serial Number |
Notes |
|
- |
- |
C-9952-B/E83569 |
4' x 18' |
|
- |
2500 Gallon |
C-9952-A |
7' x 6', NB # 38894 |
|
EL Nickell |
- |
46653 |
Year 1995, 5,000 LBS |
| - |
- |
- |
- |
Top Of Page |

| Cooling Towers |
Manufacturer |
Model |
Serial Number |
Notes |
|
BAC |
15250W |
U97418531 |
1997 Vintage, 250 Nomial Tons, Stainless Steel Water Basin, 20 HP Fan Motor, 65,400 CFM, 230/460v, 60Hz, 3Ph |
|
BAC |
15250-2W |
U041738301 |
2004 Vintage, 500 Nomial Tons, Stainless Steel Basin, 130,800 CFM, Two 20 HP Fan Motors, 230/460V, 60Hz, 3Ph |
|
BAC |
15250W |
U002466101 |
2000 Vintage, 250 Normal Tons, Stainless Steel Water Basin, 20 HP Fan Motor, 65,400 CFM, 230/460V, 60Hz, 3Ph |
| - |
- |
- |
- |
Top Of Page |

| Chillers |
Manufacturer |
Model |
Serial Number |
Notes |
|
Mueller |
AT50W F-25 |
311742 |
This is a Dual Unit That Consists of Two Heat Exchangers Seperated by a Blank Plate, Stainless Steel Plates, Gravity Ammonia System, 82 Plates, Hot Side Water Flow Rate is 134 GPM, 80º F To 50º F, 43ºF Suction Temp, Hot Water SIde Flow Rate is 100 GPM from 55ºF to 45ºF, The Cold Side is flooded ammonia with a 43ºF Suction Temp., Hot Side Water Flow Rate is 134 GPM from 80ºF to 50ºF, 43ºF Suction Temp. |
| - |
- |
- |
- |
Top Of Page |
|